Prealbumin Reagent
Cat.No.: KAI-053
Type: Reagent
Method: Immunoturbidimetric
Format: Liquid
Linearity: 0-60 mg/dL
Sample: Serum
Kit Composition:
R1: 4 X 20 mL buffer
R2: 2 X 8 mL antibody
Tests / Kit: 320 (Hitachi 717)
(Can Vary Based On Analyzer Model)
Intended Use
For the quantitative determination of human prealbumin in serum by immunoturbidimetric assay. FOR IN VITRO DIAGNOSTIC USE.
Reagent Preparation
The reagents are ready to use. They do not need to be reconstituted.
Storage and Handling
All reagents should be stored refrigerated (2-8°C). Return all reagents to 2-8°C promptly after use. Unopened reagents can be used for one year from the date of manufacture, as indicated by the expiration date on the package and bottle labels. Opened reagents can be used for one month if stored at 2-8°C.
Safety Data Sheets
Prealbumin Calibrator
Cat. No.: KAI-054C
Type: Calibrator
Kit Composition:
Calibrator A: 150 mM Sodium Chloride 1 x 1 mL
Calibrator B-F: Human Prealbumin 5 x 1 mL
Intended Use
The K-ASSAY ® Prealbumin Calibrator is intended to be used for the calibration of the K-ASSAY ® Prealbumin immunoturbidimetric assay (Cat. No. KAI-053) for quantifying prealbumin in serum specimens. FOR IN VITRO DIAGNOSTIC USE.
Calibrator Preparation
The calibrators are ready to use and do not require reconstitution.
Storage and Handling
All calibrators should be stored refrigerated (2-8°C). Return all calibrators to 2-8°C promptly after use. Unopened calibrators can be used for 24 months from the date of manufacturing as indicated on the expiration date on the package and bottle labels. Opened bottles of calibrators can be used for 1 month if stored at 2-8°C.
Liquid ITA Control
Cat. No.: K49C-4M
Type: Control
Kit Composition:
Level 1: Human Serum, 2 x 2 mL, Liquid
Level 2: Human Serum, 2 x 2 mL, Liquid
Intended Use
The K-ASSAY ® Liquid ITA Control is intended to be used as a consistent test sample of known concentration for monitoring the performance of K-ASSAY ® immunoturbidimetric assays (ITA) for the listed constituents.
Alpha-1 Acid Glycoprotein (Cat. No. KAI-021)
Alpha-1 Anti-Trypsin (Cat. No. KAI-001)
C-Reative Protein (Cat. No. KAI-026)
Complement C3 (Cat. No. KAI-009)
Complement C4 (Cat. No. KAI-010)
Haptoglobin (Cat. No. KAI-022)
IgA (Cat. No. KAI-013)
IgG (Cat. No. KAI-014)
IgM (Cat. No. KAI-015)
Prealbumin (Cat. No. KAI-053)
Transferrin (Cat. No. KAI-023)
FOR IN VITRO DIAGNOSTIC USE.
Control Preparation
Controls are liquid and ready to use.
Storage and Handling
Store controls at 2-8°C. Return all controls to 2-8° promptly after use. Unopened controls can be used for one year from the date of manufacturing as indicated by the expiration date on the package and bottle labels.
Opened controls can be used for 1 month if stored at 2-8°C.